<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.8" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
  <titleInfo>
    <title>Dynamic testing of total hip and knee replacements under physiological conditions</title>
  </titleInfo>
  <name type="personal" usage="primary">
    <namePart>Herrmann, Sven W.</namePart>
    <namePart type="date">1981-</namePart>
    <role>
      <roleTerm type="text">VerfasserIn</roleTerm>
    </role>
    <role>
      <roleTerm authority="marcrelator" type="code">aut</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Bader, Rainer</namePart>
    <namePart type="date">1965-</namePart>
    <role>
      <roleTerm type="text">GutachterIn</roleTerm>
    </role>
    <role>
      <roleTerm authority="marcrelator" type="code">oth</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Woernle, Christoph</namePart>
    <namePart type="date">1958-</namePart>
    <role>
      <roleTerm type="text">GutachterIn</roleTerm>
    </role>
    <role>
      <roleTerm authority="marcrelator" type="code">oth</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>D'Lima, Darryl D.</namePart>
    <role>
      <roleTerm type="text">GutachterIn</roleTerm>
    </role>
    <role>
      <roleTerm authority="marcrelator" type="code">oth</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Universität Rostock</namePart>
    <role>
      <roleTerm type="text">Grad-verleihende Institution</roleTerm>
    </role>
    <role>
      <roleTerm authority="marcrelator" type="code">dgg</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Universität Rostock</namePart>
    <namePart>Fakultät für Maschinenbau und Schiffstechnik</namePart>
    <role>
      <roleTerm type="text">Grad-verleihende Institution</roleTerm>
    </role>
    <role>
      <roleTerm authority="marcrelator" type="code">dgg</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marcgt">theses</genre>
  <genre authority="rdacontent">Text</genre>
  <genre authority="gnd-content">Hochschulschrift</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">gw</placeTerm>
    </place>
    <dateIssued encoding="marc">2014</dateIssued>
    <issuance>monographic</issuance>
    <place>
      <placeTerm type="code" authority="iso3166">XA-DE</placeTerm>
    </place>
  </originInfo>
  <originInfo eventType="publication">
    <place>
      <placeTerm type="text">Rostock</placeTerm>
    </place>
    <agent>
      <namePart>Universität</namePart>
      <role>
        <roleTerm>publisher</roleTerm>
      </role>
    </agent>
    <dateIssued>2014</dateIssued>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marccategory">electronic resource</form>
    <form authority="marcsmd">remote</form>
    <form type="media" authority="rdamedia">Computermedien</form>
    <form type="carrier" authority="rdacarrier">Online-Ressource</form>
    <extent>1 Online-Ressource</extent>
  </physicalDescription>
  <abstract type="Summary">Instability of total hip and knee replacements prevails as major complication. As measurements in patients are afflicted with ethical objections, this work presents a hardware-in-the-loop (HiL) approach that is capable of testing total joint stability under dynamic, reproducible and physiological conditions. An essential aspect represents its validation which includes the development of specific multibody models. In this sense, the HiL test system extends the repertoire of common approaches in orthopedic research by combining the advantages of real implant testing and model-based simulation.&lt;eng&gt;</abstract>
  <note type="statement of responsibility">by Sven W. Herrmann</note>
  <note>Die Dissertation ist auch im Verlag Dr. Hut unter der ISBN 978-3-8439-2309-5 erschienen</note>
  <note type="thesis">Dissertation Universität Rostock 2015</note>
  <classification authority="ddc">620</classification>
  <classification authority="ddc">610</classification>
  <classification authority="ddc">570</classification>
  <classification authority="bkl">76.12</classification>
  <location>
    <url displayLabel="Volltext" usage="primary display" note="kostenfrei">http://rosdok.uni-rostock.de/resolve/urn/urn:nbn:de:gbv:28-diss2016-0002-7</url>
  </location>
  <relatedItem type="otherFormat" otherType="Erscheint auch als" displayLabel="Erscheint auch als">
    <titleInfo>
      <title>Dynamic testing of total hip and knee replacements under physiological conditions</title>
    </titleInfo>
    <originInfo>
      <publisher>München : Verlag Dr. Hut, 2014</publisher>
      <edition>1. Auflage</edition>
    </originInfo>
    <physicalDescription>
      <form>XII, 118 Seiten</form>
    </physicalDescription>
    <note>Druck-Ausgabe</note>
    <identifier type="isbn">9783843923095</identifier>
    <identifier type="local">(DE-627)838445306</identifier>
    <name>
      <namePart>Herrmann, Sven W., 1981 - </namePart>
    </name>
  </relatedItem>
  <identifier type="urn">urn:nbn:de:gbv:28-diss2016-0002-7</identifier>
  <identifier type="oclc">946775355</identifier>
  <recordInfo>
    <descriptionStandard>rda</descriptionStandard>
    <recordContentSource authority="marcorg">DE-627</recordContentSource>
    <recordCreationDate encoding="marc">160413</recordCreationDate>
    <recordIdentifier source="DE-627">856740160</recordIdentifier>
    <recordChangeDate encoding="iso8601">20251224T201712.0</recordChangeDate>
    <recordOrigin>Converted from MARCXML to MODS version 3.8 using MARC21slim2MODS3-8_XSLT1-0.xsl
				(Revision 1.174 20250328)</recordOrigin>
    <languageOfCataloging>
      <languageTerm authority="iso639-2b" type="code">ger</languageTerm>
    </languageOfCataloging>
  </recordInfo>
</mods>
