  <dc:title xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Ein   Verfahren zur störungsarmen Erfassung der Pulsfrequenz unter Bewegungsbedingungen</dc:title>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Guttke, Sebastian , 1977- (VerfasserIn)</dc:contributor>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Laukner, Matthias , 1964- (GutachterIn)</dc:contributor>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Ewald, Hartmut , 1953- (GutachterIn)</dc:contributor>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Pliquett, Uwe , 1961- (GutachterIn)</dc:contributor>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Universität Rostock (Grad verleihende Institution)</dc:contributor>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Universität Rostock Fakultät für Informatik und Elektrotechnik (Grad verleihende Institution)</dc:contributor>
  <dc:type xmlns:dc="http://purl.org/dc/elements/1.1/">Text</dc:type>
  <dc:type xmlns:dc="http://purl.org/dc/elements/1.1/">theses</dc:type>
  <dc:type xmlns:dc="http://purl.org/dc/elements/1.1/">Text</dc:type>
  <dc:type xmlns:dc="http://purl.org/dc/elements/1.1/">Hochschulschrift</dc:type>
  <dc:date xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">2016</dc:date>
  <dc:date xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">[2016]</dc:date>
  <dc:language xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">ger</dc:language>
  <dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">electronic resource</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">remote</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">Computermedien</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">Online-Ressource</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">1 Online-Ressource</dc:format>
  <dc:description xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Es wurde das SNR bei den Methoden EKG, PPG, IPG und Druck zur Messung der Pulsfrequenz bei Bewegung des Nutzers untersucht. Dann wurde ein mobiler PPG-Stirnbandsensor entwickelt, womit die Gliedmaßen frei beweglich bleiben. Ein Signalkoppelmodell beschreibt die Entstehung von zwei PPG-Signalen ausgehend vom Herzschlag als gemeinsame Signalquelle mittels Übertragungsfunktionen, welche vom Messort, der Physiologie und der Ankopplung abhängig sind. Nutz- und Störsignalanteile sollen sich additiv überlagern. Ein zweistufiger adaptiver Algorithmus schätzt und entfernt den Störsignalanteil aus dem PPG.&lt;ger&gt;</dc:description>
  <dc:description xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Methods as the ECG, IPG, PPG or blood-pressure as sensors for heart rate measurements were compared while in motion. We aimed to develop a novel approach for an alternative heart-rate-monitor including a software algorithm for suppressing interfering signals. PPG-sensor showed good properties and a low SNR in motion. By using transfer functions between 2 sensor-signals an algorithm to extract the origin pulse signal from a strongly disturbed pulse signal was developed. It was possible to estimate the original form of the PPG-signal during movements like head shaking.&lt;eng&gt;</dc:description>
  <dc:description xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">vorgelegt von Sebastian Guttke aus Leipzig</dc:description>
  <dc:description xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Dissertation Universität Rostock 2016</dc:description>
  <dc:subject xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">600</dc:subject>
  <dc:subject xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">WW 8284</dc:subject>
  <dc:subject xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">50.22</dc:subject>
  <dc:subject xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">44.14</dc:subject>
  <dc:subject xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">44.85</dc:subject>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/">http://rosdok.uni-rostock.de/resolve/urn/urn:nbn:de:gbv:28-diss2017-0067-5</dc:identifier>
  <dc:relation xmlns:dc="http://purl.org/dc/elements/1.1/">Ein Verfahren zur störungsarmen Erfassung der Pulsfrequenz unter Bewegungsbedingungen--(DE-627)887435637</dc:relation>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">urn:nbn:de:gbv:28-diss2017-0067-5</dc:identifier>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">oclc: 987364360</dc:identifier>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/">ppn:
				(DE-627)887554164</dc:identifier>
</oai_dc:dc>