<?xml version="1.0"?>
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:title xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Reducing the number of monitor units in multileaf collimator field segmentation</dc:title>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Kalinowski, Thomas , 1980- (VerfasserIn)</dc:contributor>
  <dc:type xmlns:dc="http://purl.org/dc/elements/1.1/">Text</dc:type>
  <dc:type xmlns:dc="http://purl.org/dc/elements/1.1/">Text</dc:type>
  <dc:date xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">2004</dc:date>
  <dc:date xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">2004</dc:date>
  
  <dc:language xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">eng</dc:language>
  <dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">electronic resource</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">remote</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">Computermedien</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">Online-Ressource</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">1 Online-Ressource (20 Seiten)</dc:format>
  <dc:description xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Multileaf collimators (MLCs) are the prevailing tool for the realization of radiation fields in intensity modulated radiation therapy (IMRT). One step in the treatment planning is to determine a set of leaf positions realizing a certain intensity modulated radiation field. In this paper we suggest two extensions in the use of the MLC that lead to considerable savings in terms of monitor units, thus potentially increasing the treatment quality. We test our method with random and with clinical sample matrices.&lt;eng&gt;</dc:description>
  <dc:rights xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Open Access</dc:rights>
  <dc:rights xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Urheberrechtsschutz 1.0</dc:rights>
  <dc:description xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Thomas Kalinowski</dc:description>
  <dc:subject xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">510</dc:subject>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/">https://purl.uni-rostock.de/rosdok/id00005902</dc:identifier>
  <dc:relation xmlns:dc="http://purl.org/dc/elements/1.1/">Reducing the number of monitor units in multileaf collimator field segmentation--(DE-627)468507280</dc:relation>
  
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">urn:nbn:de:gbv:28-rosdok_id00005902-1</dc:identifier>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">doi: 10.18453/rosdok_id00005902</dc:identifier>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">oclc: 1621961111</dc:identifier>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/">ppn:
				(DE-627)1987272293</dc:identifier>
</oai_dc:dc>
