<?xml version="1.0"?>
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:title xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Einfluss von Schraubengeometrie und Knochenmorphologie auf das Insertionsverhalten kieferorthopädischer Minischrauben</dc:title>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Kauza, Anna , 1990- (VerfasserIn)</dc:contributor>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Stahl, Franka , 1974- (AkademischeR BetreuerIn)</dc:contributor>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Warkentin, Mareike , 1980- (AkademischeR BetreuerIn)</dc:contributor>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Wilmes, Benedict , 1969- (AkademischeR BetreuerIn)</dc:contributor>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Universität Rostock (Grad-verleihende Institution)</dc:contributor>
  <dc:contributor xmlns:dc="http://purl.org/dc/elements/1.1/">Universitätsmedizin Rostock (Grad-verleihende Institution)</dc:contributor>
  <dc:type xmlns:dc="http://purl.org/dc/elements/1.1/">Text</dc:type>
  <dc:type xmlns:dc="http://purl.org/dc/elements/1.1/">theses</dc:type>
  <dc:type xmlns:dc="http://purl.org/dc/elements/1.1/">Text</dc:type>
  <dc:type xmlns:dc="http://purl.org/dc/elements/1.1/">Hochschulschrift</dc:type>
  <dc:date xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">2024</dc:date>
  <dc:date xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">2024</dc:date>
  
  <dc:language xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">ger</dc:language>
  <dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">electronic resource</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">remote</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">Computermedien</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">Online-Ressource</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">application/pdf</dc:format><dc:format xmlns:dc="http://purl.org/dc/elements/1.1/">1 Online-Ressource (I, 95 Seiten) Illustrationen, Diagramme</dc:format>
  <dc:description xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Die Studie untersuchte, wie das Design kieferorthopädischer Mini-Implantate (MI) und die Kortikalisdicke das Eindrehmoment beeinflussen. MIs wurden in künstlichem Knochen und im porcinen Beckenkamm getestet. Das Eindrehmoment variierte je nach MI-Typ und Kortikalisdicke. Elf von zwölf Schraubengeometrie-Parametern korrelierten mit dem Eindrehmoment. Die Ergebnisse betonen die Bedeutung eines an die Kortikalisdicke angepassten Designs zur Sicherung der primären Stabilität und Vermeidung von Schraubenbrüchen.&lt;ger&gt;</dc:description>
  <dc:description xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">The study investigated how the design of orthodontic mini-implants (MIs) and cortical bone thickness affect insertion torque. MIs were tested in artificial bone and porcine iliac crest with varying cortical thicknesses. Insertion torque varied depending on MI type and cortical thickness. Eleven of twelve screw geometry parameters correlated with torque. The results highlight the importance of MI designs adapted to cortical thickness to ensure primary stability and prevent screw fractures.&lt;eng&gt;</dc:description>
  <dc:rights xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Open Access</dc:rights>
  <dc:rights xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Urheberrechtsschutz 1.0</dc:rights>
  <dc:description xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">vorgelegt von Anna Kauza</dc:description>
  <dc:description xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">GutachterInnen: Franka Stahl (Klinik und Polikliniken für Zahn-, Mund- und Kieferheilkunde, Universitätsmedizin Rostock) ; Mareike Warkentin (Fakultät für Maschinenbau und Schiffstechnik, AG Implantatwerkstoffe, Universität Rostock) ; Benedict Wilmes (Poliklinik für Kieferorthopädie, Heinrich-Heine-Universität Düsseldorf)</dc:description>
  <dc:description xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">Dissertation Universität Rostock 2025</dc:description>
  <dc:subject xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">610</dc:subject>
  <dc:subject xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">617.64</dc:subject>
  <dc:subject xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">610</dc:subject>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/">https://purl.uni-rostock.de/rosdok/id00005137</dc:identifier>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/">https://doi.org/10.18453/rosdok_id00005137</dc:identifier>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/">https://nbn-resolving.org/urn:nbn:de:gbv:28-rosdok_id00005137-3</dc:identifier>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/">https://d-nb.info/1391763769/34</dc:identifier>
  <dc:relation xmlns:dc="http://purl.org/dc/elements/1.1/">Einfluss von Schraubengeometrie und Knochenmorphologie auf das Insertionsverhalten kieferorthopädischer Minischrauben--(DE-627)1963159934</dc:relation>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">urn:nbn:de:gbv:28-rosdok_id00005137-3</dc:identifier>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">doi: 10.18453/rosdok_id00005137</dc:identifier>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:srw_dc="info:srw/schema/1/dc-schema">oclc: 1574785469</dc:identifier>
  <dc:identifier xmlns:dc="http://purl.org/dc/elements/1.1/">ppn:
				(DE-627)1963159594</dc:identifier>
</oai_dc:dc>
